  • 85e620392fb65a115f126bd15e8668c(1717731163297).jpg

Fire-resistant wire and cable

  • Commodity name: Fire-resistant wire and cable
Fire-resistant PVC insulated wire and cable: GB/T 503-2008 "rated 450/750V and below PVC insulated cable". JB/T 8734-199 "Polychloroethylene Insulated Cables, Wires and Flexible Cords with Rated Electricity of 450/750V and Below". GB/T 1966-2005 "flame retardant and fire resistant wire and cable general rules". GA 306.1-2007, Classification and Requirements for Flame Retardant and Fire Resistant Cables with Plastic Insulation. Fire-resistant PVC (XLPE) insulated control cable: GB/T 9330-2008 "plastic insulated control cable". GB/T 19666-2005 "flame retardant and fire resistant wire and cable general". GA 306.1-2007, Classification and Requirements for Flame Retardant and Fire Resistant Cables with Plastic Insulation. Fire-resistant PVC (XLPE) insulated power cables: GB/T 12706-2008 "rated voltage 11KV(Um = 1.2KV) to 35KV(Um-40.5KV) extruded insulated power cables and accessories". GB/T 19666-2005 "flame retardant and fire resistant wire and cable general". GA 306.1-2007, Classification and Requirements for Flame Retardant and Fire Resistant Cables with Plastic Insulation.

Classification:

Technical Support:

Enterprise E-mail:

  • Product Description
  • 1. product standards
    Fire-resistant PVC insulated wire and cable: GB/T 503-2008 "rated 450/750V and below PVC insulated cable". JB/T 8734-199 "Polychloroethylene Insulated Cables, Wires and Flexible Cords with Rated Electricity of 450/750V and Below". GB/T 1966-2005 "flame retardant and fire resistant wire and cable general rules". GA 306.1-2007, Classification and Requirements for Flame Retardant and Fire Resistant Cables with Plastic Insulation. Fire-resistant PVC (XLPE) insulated control cable: GB/T 9330-2008 "plastic insulated control cable". GB/T 19666-2005 "flame retardant and fire resistant wire and cable general". GA 306.1-2007, Classification and Requirements for Flame Retardant and Fire Resistant Cables with Plastic Insulation. Fire-resistant PVC (XLPE) insulated power cables: GB/T 12706-2008 "rated voltage 11KV(Um = 1.2KV) to 35KV(Um-40.5KV) extruded insulated power cables and accessories". GB/T 19666-2005 "flame retardant and fire resistant wire and cable general". GA 306.1-2007, Classification and Requirements for Flame Retardant and Fire Resistant Cables with Plastic Insulation.

    2. scope of application
    Suitable for power plants, high-rise buildings, oil fields, telephones, power plants, mines, chemicals, subways and other control, monitoring circuits, protection lines require high fire conditions, and is an ideal product for emergency power supplies, fire pumps, elevators, and communication signal systems.

    3. fire-resistant wire and cable features:
    This product has a high fire resistance, in the case of flame combustion, can maintain a certain period of safe operation, in order to carry out emergency fire, rescue personnel, such as dredging glue work, reduce fire losses.

    Model, grade and technical requirements of 4. fire-resistant wire and cable

    Model

    Level

    Fire temperature ℃

    Fire supply time min

    Conclusion

    Toxic concentration of flue gas g/I

    Smoke density transmittance%

    NH

    Level I IA

    950~1000

    90

    3A Fuse

    No fusing

    ≥ 12.4

    ≥80

    Level I IB

    850

    90

    Level II IIA

    950~1000

    90

    3A Fuse

    No fusing

    ≥ 12.4

    ≥ 60

    Level II IIB

    850

    90

    Level III IIIA

    950~1000

    90

    3A Fuse

    No fusing

    ≥ 6.05

    ≥ 20

    Level III IIIB

    850

    90

    Level IV IVA

    950~1000

    90

    3A Fuse

    No fusing

    -

    -

    Level IV IVB

    850

    90

     

    Model, specification and production scope of 5. flame retardant wire and cable
    See Hangzhou Zhongce Cable Co., Ltd. wire and cable product samples.

    6. structure size and main technical parameters
    See Hangzhou Zhongce Cable Co., Ltd. wire and cable product samples.

    7. Delivery Length
    According to the agreement of both parties, the length measurement error is 0.5.

    8. Service
    Provide non-standard products and technical support according to the special requirements of users.


     

Get Quote

Note: Please leave your mobile phone or E-mail and our professionals will contact you as soon as possible!

Zhongce Cable

A professional manufacturer of power cables, control cables, overhead stranded wires, overhead insulated cables, PVC insulated cables (wires), electronic computer cables, intrinsically safe cables, compensation wires and cables, high temperature wires and cables, inverter cables, silicone rubber cables, Rubber sheathed cables, mining cables, marine cables, communication cables, pre-branch cables, magnesium oxide cables, local network cables, telephone wires, parallel cluster wires, etc. are flame-retardant, fire-resistant, low-smoke, low-halogen, low-smoke halogen-free series, manufacturers of low-voltage electrical appliances, switches, sockets and related ancillary products.

Hangzhou Zhongce Cable Co., Ltd.

Telephone:0571-87673333

Telephone:0571-86726602

Mobile phone number:18057195879General Lu

Fax:0571-86935921

E-mail:hzzc.dxdl@163.com

Address: No.58, No.10 Street, Jianggan District, Hangzhou City, Zhejiang Province

 

Zhongce Cable

Sweep, get the brochure

Zhongce

Mobile phone view

All rights reserved©2024 Hangzhou Zhongce Cable Co., Ltd. |

Business License
SEO